Denver Egress HelpEscape windows for basements on Front Range clay · Denver, CO

Denver's Egress Window Code, Section by Section

Denver writes its residential code as a list of changes to a national model code. For escape windows the model rules carry over almost untouched, with one Denver addition worth knowing before you replace or buy.

Request an egress window visitRead the FAQ

Denver adopted the 2024 IRC as the Denver Residential Code on June 13, 2025. Section R319 requires an escape opening in every basement and sleeping room: 5.7 sq ft clear, 24 in high, 20 in wide, sill at most 44 in. Denver adds one rule: a replacement escape window must still give 4 sq ft, 22 in by 20 in.

Which code edition does Denver use?

The 2025 Denver Building and Fire Code, adopted June 13, 2025, incorporates the 2024 International Building, Residential, Existing Building, Mechanical, Plumbing, Fuel Gas and Fire Codes, with the 2021 energy code. A transition of about six months followed in which either the 2022 or the 2025 Denver code could be used. The residential part is called the Denver Residential Code (DRC). In the 2024 edition, escape openings moved from section R310 to R319, so newer Denver documents cite R319.

What counts as a sleeping room in Denver?

The DRC defines a sleeping room as "any room used or intended to be used for sleeping purposes." Use decides it, not size or a closet. Each one needs its own escape opening (R319.1), in line with Ready.gov's advice to know two ways out of every room. When an existing basement is altered without creating a sleeping room, no new opening is required (R319.7).

A basement apartment is a separate question. Denver treats a space as its own dwelling unit when it has provisions for living, cooking, sanitation, bathing and sleeping, and independent egress to the outside from an egress door (DRC R101.2.6). That door is in addition to the bedroom window.

Denver's rule for replacement escape windows

The model code lets a replacement window skip the full escape sizes if it is the largest standard size that fits the existing frame or rough opening, opens as much as or more than the old style, and is not part of a change of occupancy (R319.5). Denver adds a third condition: the window must provide at least 4 sq ft of net clear opening, 22 in of clear height and 20 in of clear width. The same 4 sq ft, 22 in and 20 in floor applies when a change of occupancy calls for an escape opening (Appendix BO108.8.3).

A same-size swap with no structural change needs no building permit, except on a designated landmark or in a historic district, or where safety glazing is required.

Permits, drawings and landmark review

Denver's permit checklist for new homes and additions asks drawings to show an escape opening in the basement and every sleeping room, label each window's width, height and sill height, and dimension each well's length and width against the zoning code's setback exceptions. Landmark Preservation reviews egress windows on all individual landmarks and on every property in a historic district, and a Certificate of Appropriateness comes before the building permit. The city's Development Services map shows a property's landmark status.

For the work itself, see cutting an egress opening and wells and covers; for prices, the Denver egress window cost guide.

Which basement wall are you thinking about?

A line or two is plenty: a bedroom planned downstairs, a window up by the joists, a well that fills with snow, a crack in the wall. One independent specialist who works in Denver will get in touch to talk it through.

What's going on?

Only the local specialist gets it, to reach you about this.

Free to ask. No obligation. Many local specialists don't charge for the first visit; ask when they call.

This site is run by a referral service that is paid by the specialists it connects you with. Asking costs you nothing.

A local egress window installer who serves Denver will call you back. Your request goes to that one independent specialist, not a list. By sending this you agree they may call or text you about it. Privacy.

Request egress window visitSee prices